SAUDI ARAMCO :: ELECTRICAL INSPECTION CHECKLISTS AND SA TEST REPORTS INDEX [Excel Download Free]

QC-SKILLS
By -
0

 SATIP INDEX - ELECTRICAL

SAUDI ARAMCO :: ELECTRICAL INSPECTION CHECKLISTS AND SA TEST REPORTS INDEXSAUDI ARAMCO  ELECTRICAL INSPECTION CHECKLISTS AND SA TEST REPORTS INDEX 

1 AC UPS Systems : SATIP-P-103-01

General - Electronic Equipment, Storage Handling & Preservation - SAIC-P-3001

General - Electrical Equipment, Storage Handling & Preservation - SAIC-P-3002

General - Switchgear Room / Substation, Equipment Pre-Installation Inspection - SAIC-P-3003

UPS/DC Vented Ni-Cad Wet Cell, Storage Handling & Preservation - SAIC-P-3101

UPS/DC Vented Lead-Acid Wet Cell, Storage Handling & Preservation - SAIC-P-3102

UPS/DC Valve Regulated Lead-Acid (VRLA) Gelatin Cell, Storage Handling & Preservation - SAIC-P-3103

UPS/DC Aqueous Sulfuric Acid Electrolyte, Storage Handling & Preservation - SAIC-P-3104

UPS/DC Dry Potassium or Sodium Hydroxide Electrolyte, Storage Handling & Preservation - SAIC-P-3105

UPS DC/AC Inverter, Material Receiving - SAIC-P-3106

UPS Static Switch, Material Receiving - SAIC-P-3107

UPS Transfer Switch Material Receiving - SAIC-P-3108

UPS Bypass Line Transformer Material Receiving - SAIC-P-3109

UPS Maintenance Bypass Switch Material Receiving - SAIC-P-3110

UPS Panelboards / CB's Material Receiving - SAIC-P-3111

UPS/DC Battery Rectifier / Charger Material Receiving - SAIC-P-3112

UPS/DC Vented Ni-Cad Wet Cell Material Receiving - SAIC-P-3113

UPS/DC Vented Lead-Acid Wet Cell Material Receiving - SAIC-P-3114

UPS/DC VRLA Gelatin Cell Material Receiving - SAIC-P-3115

UPS/DC Aqueous Sulfuric Acid Electrolyte Material Receiving - SAIC-P-3116

UPS/DC Dry Potassium or Sodium Hydroxide Material Receiving - SAIC-P-3117

UPS/DC System and Battery Accessories, Material Receiving - SAIC-P-3118

UPS/DC Battery Room, Equipment Pre-Installation Inspection - SAIC-P-3119

UPS/DC Equipment and Battery Rack, Installation and Pre-Commissioning - SAIC-P-3120

UPS/DC System Electrochemical Battery Installation and Pre-Commissioning - SAIC-P-3121

UPS/DC Electrochemical Battery, Storage and Preservation Testing - SATR-P-3101

UPS/DC Vented Ni-Cad Wet Cell, Jobsite Acceptance Test - SATR-P-3102

UPS/DC Vented Lead-Acid Wet Cell, Jobsite Acceptance Test - SATR-P-3103

UPS/DC Valve-Regulated Lead-Acid (VRLA) Gelatin Cell, Jobsite Acceptance Test - SATR-P-3104

UPS DC/AC Inverter, Pre-Commissioning & Functional Testing - SATR-P-3105

UPS Static Switch, Pre-Commissioning & Functional Testing - SATR-P-3106

UPS Transfer Switch, Pre-Commissioning & Functional Testing - SATR-P-3107

UPS Bypass Line Transformer, Pre-Commissioning & Functional Testing - SATR-P-3108

UPS Maintenance Bypass Switch, Pre-Commissioning & Functional Testing - SATR-P-3109

UPS Panelboards / CB's, Pre-Commissioning & Functional Testing - SATR-P-3110

UPS/DC Battery Rectifier / Charger, Pre-Commissioning & Functional Testing - SATR-P-3111

UPS Distribution System, Energized Bolted-Fault Test - SATR-P-3112

UPS/DC Vented Ni-Cad Wet Cell, Battery Pre-Commissioning Test - SATR-P-3113

UPS/DC Vented Lead-Acid Wet Cell, Battery Pre-Commissioning Test - SATR-P-3114

UPS/DC Valve-Regulated Lead-Acid (VRLA) Gelatin Cell, Battery Pre-Commissioning Test - SATR-P-3115


2 Direct Current Power Systems : SATIP-P-103-02

DC Switchboard / CB's, Material Receiving - SAIC-P-3122

DC Panelboard / CB's, Material Receiving - SAIC-P-3123

DC Switchboard / CB's, Pre-Commissioning & Functional Testing - SATR-P-3116

DC Switchboard / CB's, Pre-Commissioning & Functional Testing - SATR-P-3117

0 Low Voltage (600V to 1kV) Cable : SATIP-P-104-01

General - Hazardous Location Conduit and Cable Sealing Special Work Procedure, Document Review - SAIC-P-3004

Cable Storage, Handling, & Preservation - SAIC-P-3201

Low Voltage UL / NEC Power and Control Cable, Material Receiving - SAIC-P-3202

Low Voltage NEC / SASO / IEC Unjacketed Wire, Material Receiving - SAIC-P-3203

Low Voltage IEC Armored Cable, Material Receiving - SAIC-P-3204

Low Voltage IEC Unarmored Cable, Material Receiving - SAIC-P-3205

Low Voltage Power Cable Accessories, Material Receiving - SAIC-P-3206

Low Voltage Power and Control Cable, Installation and Pre-Commissioning - SAIC-P-3207

Low Voltage Building Wire, Installation and Pre-Commissioning - SAIC-P-3208

Hazardous Location Conduit / Cable Seal Fitting Installation and Sealing - SAIC-P-3209

Low Voltage Power and Control Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3201

Low Voltage Building Wire (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3202

Low Voltage Power and Control Cable, Continuity and Megger Insulation Resistance Testing - SATR-P-3203

Low Voltage Building Wire, Continuity and Megger Insulation Resistance Testing - SATR-P-3204

Low Voltage Power and Control Cable, Termination Torque Testing - SATR-P-3205

Low Voltage Building Wire, Termination Torque Testing - SATR-P-3206


3 Medium Voltage (1.0kV to 35kV) Cable : SATIP-P-104-02

Medium Voltage UL / NEC Cable, Material Receiving - SAIC-P-3211

Medium Voltage IEC Cable, Material Receiving - SAIC-P-3212

Medium Voltage Power Cable Accessories, Material Receiving - SAIC-P-3213

Medium Voltage Cable, Installation and Pre-Commissioning - SAIC-P-3214

Medium Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3207

Medium Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3208

Medium Voltage Power Cable, Termination Torque Testing - SATR-P-3209

Medium Voltage Power Cable, High-Potential Withstand Testing - SATR-P-3210

Download SATIP Index xlsx  file

4 Cable Tray, Fittings and Accessories : SATIP-P-104-03

Cable Tray and Accessories, Storage Handling & Preservation - SAIC-P-3301

Cable Tray, Metallic Tray Systems, Material Receiving - SAIC-P-3302

Cable Tray, Non-Metallic Tray Systems, Material Receiving - SAIC-P-3303

Cable Tray, Non-Metallic Tray Accessories, Material Receiving - SAIC-P-3305

Cable Tray Firewall Barriers, Material Receiving - SAIC-P-3306

Cable Tray, Metallic Tray Systems, Installation and Pre-Commissioning - SAIC-P-3307

Cable Tray, Non-Metallic Tray Systems, Installation and Pre-Commissioning - SAIC-P-3308

Cable Tray Firewall Barriers, Installation and Pre-Commissioning - SAIC-P-3309

Cable Tray, NEMA VE1 Static Load Testing - SATR-P-3301


5 Boxes (Junction, Terminal and Pull) Wire Troughs & Wireways : SATIP-P-104-04

General Boxes and Enclosures - Material Receiving - SAIC-P-3007

General Boxes and Enclosures - Metallic Wireways and Access, Material Receiving - SAIC-P-3008

General Boxes and Enclosures - Non-metallic Wireways and Access, Material Receiving - SAIC-P-3009

General Boxes and Enclosures - Pushbutton and Pilotlight Control Stations and Access, Material Receiving - SAIC-P-3010

General Boxes and Enclosures - Non-Hazardous Indoor Enclosures, Installation and Pre-Commissioning - SAIC-P-3014

General Boxes and Enclosures - Non-Hazardous Outdoor Enclosures, Installation and Pre-Commissioning - SAIC-P-3015

General Boxes and Enclosures - Class I, Division 1 or Zone 1, Hazardous Location Enclosures (Indoor and Outdoor), Installation, and Pre-Commissioning - SAIC-P-3016

General Boxes and Enclosures - Class I, Division 2 or Zone 2, Hazardous Location Enclosures (Indoor and Outdoor), Installation, and Pre-Commissioning - SAIC-P-3017


6 Above-Grade Conduits, Fittings and Accessories : SATIP-P-104-05

Conduit - Storage, Handling, and Preservation - SAIC-P-3310

Conduit - Galvanized Rigid Steel (GRS) Conduit, Material Receiving - SAIC-P-3311

Conduit - Flexible Metal Conduit (FMC), Material Receiving - SAIC-P-3313

Conduit - Liquid-Tight Flexible Metal Conduit (LT Flex), Material Receiving - SAIC-P-3314

Conduit - Explosion-Proof Flexible Metal Couplings (EXP Flex), Material Receiving - SAIC-P-3315

Conduit - Electrical Metallic Tubing (EMT), Material Receiving - SAIC-P-3316

Conduit - EXP Fittings and Accessories, Material Receiving - SAIC-P-3317

Conduit - EMT & FMC Fittings and Accessories, Material Receiving - SAIC-P-3318

Conduit - GRS Fittings and Accessories, Material Receiving - SAIC-P-3319

Conduit - LT Flex Fittings and Accessories, Material Receiving - SAIC-P-3320

Conduit - Hazardous Location GRS & LT Flex Conduit Systems (Class I, Zone or Div 2), Installation and Pre-Commissioning - SAIC-P-3321

Conduit - Hazardous Location GRS & EXP Flex Conduit Systems (Class I, Zone or Div 1), Installation and Pre-Commissioning - SAIC-P-3322

Conduit - PVC-Coated GRS Conduit Systems (HL and NHL), Installation and Pre-Commissioning - SAIC-P-3323

Conduit - GRS & LT Flex Conduit Systems (NHL), Installation and Pre-Commissioning - SAIC-P-3324

Conduit - EMT & FMC Raceway Systems (NHL), Installation and Pre-Commissioning - SAIC-P-3325


7 Below-Grade Conduit, Fittings and Accessories : SATIP-P-104-07

Pre-cast Ductbank / MH / HH, Jobsite Storage, Handling and Preservation - SAIC-P-3327

Ductbank PVC Conduit, Material Receiving - SAIC-P-3328

Pre-cast Ductbank, Fabrication and Jobsite Material Receiving - SAIC-P-3331

Ductbank / MH / HH Excavation, Trenching, and Backfilling - SAIC-P-3333

Cast-in-Place Ductbank Fabrication - SAIC-P-3334

Manhole / Handhole Fabrication (Pre-Cast and Cast in Place) - SAIC-P-3335

Ductbank Installation and Conduit Termination and Capping - SAIC-P-3336

Ductbank / MH / HH Grounding and Bonding, Installation and Pre-Commissioning - SAIC-P-3337


8 HVAC Equipment : SATIP-P-104-08

HVAC - Control Panel - Material Receiving, Installation and Pre-Commissioning - SAIC-P-3401

HVAC - Air Cooled Condenser - Material Receiving, Installation and Pre-Commissioning - SAIC-P-3402

HVAC - Air Handler Unit (AHU) - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3403

HVAC - Centrifugal and Axial Fan - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3404

HVAC - Air Cooled Chiller - Material Receiving, Installation, and Pre-Commissioning - SAIC-P-3405

HVAC - E & I Installation for Pressurized Building Inspection - SAIC-P-3406

HVAC System - De-energized Testing - SATR-P-3401

HVAC System - Energized Functional Testing & Motor Four Hour Run Test - SATR-P-3402


9 Electrical Heat Tracing : SATIP-P-104-09

Heat Tracing - Control Panel - Material Receiving - SAIC-P-3501

Heat Tracing - Thermostat, Ambient - Material Receiving - SAIC-P-3502

Heat Tracing - Thermostat, Capillary Tube & Bulb - Material Receiving - SAIC-P-3503

Heat Tracing - Thermostat, RTD - Material Receiving - SAIC-P-3504

Heat Tracing - Contactor - Material Receiving - SAIC-P-3505

Heat Tracing - Tank Heating Pads - Material Receiving - SAIC-P-3506

Heat Tracing - Instrument Housing - Material Receiving - SAIC-P-3507

Heat Tracing - Mineral Insulated (MI) Cable - Material Receiving - SAIC-P-3508

Heat Tracing - Self-Regulating Cable - Material Receiving - SAIC-P-3509

Heat Tracing - Constant-Wattage Cable - Material Receiving - SAIC-P-3510

Heat Tracing - Power-Limiting Cable - Material Receiving - SAIC-P-3511

Heat Tracing - Cable Accessories - Material Receiving - SAIC-P-3512

Heat Tracing System - Pre-Installation Visual Inspection - SAIC-P-3513

Heat Tracing - Mineral Insulated (MI) Cable - Installation and Pre-Commissioning - SAIC-P-3514

Heat Tracing - Self-Regulating Cable - Installation and Pre-Commissioning - SAIC-P-3515

Heat Tracing - Constant-Wattage Cable - Installation and Pre-Commissioning - SAIC-P-3516

Heat Tracing - Power-Limiting Cable - Installation and Pre-Commissioning - SAIC-P-3517

Heat Tracing - Tank Heating Pads - Installation and Pre-Commissioning - SAIC-P-3518

Heat Tracing - Instrument Housing - Installation and Pre-Commissioning - SAIC-P-3519

Heat Tracing - Pre-Traced Tubing - Installation and Pre-Commissioning - SAIC-P-3520

Heat Tracing - Power Connection Kit - Installation and Pre-Commissioning - SAIC-P-3521

Heat Tracing - Tee Kit - Installation and Pre-Commissioning - SAIC-P-3522

Heat Tracing - Spice Kit - Installation and Pre-Commissioning - SAIC-P-3523

Heat Tracing - End Seal and End-of-Circuit Kit - Installation and Pre-Commissioning - SAIC-P-3524

Heat Tracing - Control Panel - Installation and Pre-Commissioning - SAIC-P-3525

Heat Tracing - Thermostat, Ambient - Installation and Pre-Commissioning - SAIC-P-3526

Heat Tracing - Thermostat, Capillary Tube & Bulb - Installation and Pre-Commissioning - SAIC-P-3527

Heat Tracing - Thermostat, RTD - Installation and Pre-Commissioning - SAIC-P-3528

Heat Tracing - Contactor - Installation and Pre-Commissioning - SAIC-P-3529

HVAC System - Thermostat - Ambient, Bench Calibration - SATR-P-3403

HVAC System - Thermostat - Capillary Tube & Bulb, Bench Calibration - SATR-P-3404

HVAC System - Thermostat - RTD, Bench Calibration - SATR-P-3405

Heat Tracing - Cable Continuity and Insulation Resistance Testing (On Cable Reel) - SATR-P-3501

Heat Tracing - Tank Heating Pads Continuity and Insulation Resistance Testing - SATR-P-3502

Heat Tracing - Instrument Housing Continuity and Insulation Resistance Testing - SATR-P-3503

Heat Tracing - Cable Continuity and Insulation Resistance Testing (Installed Circuit) - SATR-P-3504

Heat Tracing - Circuit Energized Functional Testing - SATR-P-3505


10 High Voltage (35.001kV to 69kV) Cable : SATIP-P-104-10

High Voltage Cable - Material Receiving - SAIC-P-3216

High Voltage Cable Accessories - Material Receiving - SAIC-P-3217

High Voltage Cable - Installation and Pre-Commissioning - SAIC-P-3218

High Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3211

High Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3212

High Voltage Power Cable, Termination Torque Testing - SATR-P-3213

High Voltage Power Cable, High-Potential Withstand Testing - SATR-P-3214


11 Very High Voltage (Above 69kV) Cable : SATIP-P-104-11

Very High Voltage Cable - Material Receiving - SAIC-P-3220

Very High Voltage Cable Accessories - Material Receiving - SAIC-P-3221

Very High Voltage Cable - Installation and Pre-Commissioning - SAIC-P-3222

Very High Voltage Power Cable (On Reel), Continuity and Megger Insulation Resistance Testing - SATR-P-3215

Very High Voltage Power Cable (Installed), Continuity and Megger Insulation Resistance Testing - SATR-P-3216

Very High Voltage Power Cable, Termination Torque Testing - SATR-P-3217

Very High Voltage Power Cable, Very High-Potential Withstand Testing - SATR-P-3218


12 Receptacles and Cord-Connected Equipment : SATIP-P-104-12

Receptacles & Cords - Pin-and-Sleeve Receptacle / Plug - Material Receiving - SAIC-P-3601

Receptacles & Cords - NEMA Receptacle / Plug - Material Receiving - SAIC-P-3602

Receptacles & Cords - Flexible Cord - Material Receiving - SAIC-P-3603

Receptacles & Cords - Cable Reels - Material Receiving - SAIC-P-3604

Receptacles & Cords - Festoon Systems - Material Receiving - SAIC-P-3605

Receptacles & Cords - Festoon Systems - Installation - SAIC-P-3606

Receptacles & Cords - Flexible Cord, Continuity and Insulation Resistance Testing (On cable reel) - SATR-P-3601

Receptacles & Cords - Flexible Cord, Continuity and Insulation Resistance Testing (Installed Cord, Cable, and Wire) - SATR-P-3602

Receptacles & Cords - Pin-and-Sleeve Receptacle / Plug - Installation, Functional and Polarity Testing - SATR-P-3603

Receptacles & Cords - NEMA Receptacle / Plug - Installaiton, Functional and Polarity Testing - SATR-P-3604

Receptacles & Cords - Cable Reels - Installation, Functional and Polarity Testing - SATR-P-3605

Receptacles & Cords - Festoon Systems - Installation, Functional and Polarity Testing - SATR-P-3606


13 Over-Head Transmission and Distribution Systems : SATIP-P-107-01

Overhead T&D Cable Termination and Splicing Special Work Procedure, Document Review - SAIC-P-3223

Overhead T&D Power Pole - Wood, Storage and Material Receiving - SAIC-P-3224

Overhead T&D Power Pole - Galvanized Steel, Storage and Material Receiving - SAIC-P-3226

Overhead T&D Power Structure - Galv. Lattice Steel, Storage and Material Receiving - SAIC-P-3228

Overhead T&D ACSR/AW Cable, Material Receiving - SAIC-P-3229

Overhead T&D Surge Arresters, Material Receiving - SAIC-P-3230

Overhead T&D Capacitor Banks, Material Receiving - SAIC-P-3231

Overhead T&D Metering Cabinet, Material Receiving - SAIC-P-3233

Overhead T&D Circuit Accessories, Material Receiving - SAIC-P-3234

Overhead T&D Power Pole, Installation - SAIC-P-3235

Overhead T&D Power Structure, Installation - SAIC-P-3236

Overhead T&D Equipment Installation and Pre-Commissioning - SAIC-P-3237

Overhead T&D Cable, Installation and Pre-Commissioning - SAIC-P-3238

Overhead T&D - Circuit Polarity, Continuity and Insulation Resistance Testing - SATR-P-3219

Overhead T&D - High-Potential Withstand Testing - SATR-P-3220

Overhead T&D - Cable Termination Torque Testing - SATR-P-3221

Overhead T&D - Surge Arresters, Functional Testing - SATR-P-3222

Overhead T&D - Capacitor Banks, Functional Testing - SATR-P-3223

Overhead T&D - Metering Cabinet, Functional Testing - SATR-P-3225


14 Grounding / Bonding : SATIP-P-111-01

General - Exothermic (Thermite) Welding Materials, Molds, & Tools - Material Receiving - SAIC-P-3018

GES - DCS/ESD/PLC/SCADA Grounding Installation - SAIC-P-3124

GEC/EGC - AC UPS System Grounding - SAIC-P-3125

GEC/EGC - DC System Grounding Installation - SAIC-P-3126

Grounding - GES - Ground Rods - Material Receiving - SAIC-P-3701

Electrical Grounding System - Final Inspection - SAIC-P-3702

Grounding - GES - Zinc and Magnesium Anode Electrodes - Material Receiving - SAIC-P-3704

Grounding - GES - Ground Electrode Cable - Material Receiving - SAIC-P-3705

Grounding - Bare Copper Ground Conductor - Material Receiving - SAIC-P-3706

Grounding - Bare Tinned Copper Ground Conductor - Material Receiving - SAIC-P-3707

Grounding - Hydraulic Compression Fittings and Tools - Material Receiving - SAIC-P-3708

Grounding and Bonding Accessories - Material Receiving - SAIC-P-3709

Grounding - Neutral Ground Resistor - Material Receiving - SAIC-P-3710

Grounding - GES - Copper, Copper-Clad Steel, Galvanized Steel Rod Installation - SAIC-P-3711

Grounding - GES - Zinc and Magnesium Anode Electrode Installation - SAIC-P-3712

Grounding - GES/GEC - Exothermic (Thermite) Welding Installation - SAIC-P-3713

Grounding - GES/GEC/EGC - Hydraulic Compression Connectors Installation - SAIC-P-3714

Grounding - GES - Concrete Embedded Copper Electrode Installation - SAIC-P-3715

Grounding - GES - Piping Electrode Installation - SAIC-P-3716

Grounding - GES - Structural Steel Electrode Installation - SAIC-P-3717

Grounding - GES - Copper Conductor Ground Ring Installation - SAIC-P-3718

Grounding - GES - Power Ground Electrode System (GES) Installation - SAIC-P-3719

Grounding - GES - Substation Grounding Installation - SAIC-P-3720

Grounding - GES - Cathodic Protection Grounding Installation - SAIC-P-3721

GES - Offshore Grounding Installation - SAIC-P-3722

GES - Telecommunications Grounding System Installation - SAIC-P-3723

GEC - High Resistance Grounding Installation - SAIC-P-3724

GEC - LV Dry Transformer Grounding Installation - SAIC-P-3725

GEC/EGC - Panelboard Grounding Installation - SAIC-P-3726

GEC/EGC - Switchgear / Controlgear Grounding Installation - SAIC-P-3727

GEC/EGC - DG Set System Grounding Installation - SAIC-P-3728

GEC/EGC - ATS / MTS System Grounding Installation - SAIC-P-3729

GEC/EGC - Pad-Mounted Transformer Grounding Installation - SAIC-P-3730

GEC/EGC - Power Transformer Grounding Installation - SAIC-P-3731

GEC/EGC - Variable Speed Drive Grounding Installation - SAIC-P-3732

EGC - Cable Tray Grounding / Bonding Installation - SAIC-P-3733

EGC - Conduit Grounding / Bonding  Installation - SAIC-P-3734

EGC - Buried Cable Grounding / Bonding Installation - SAIC-P-3735

EGC - Ductbank Grounding / Bonding Installation - SAIC-P-3736

EGC - Electrical Eqpt. Grounding / Bonding Installation - SAIC-P-3737

EGC - Instrumentation Grounding / Bonding / Shielding Installation - SAIC-P-3738

EGC - Surge Arrestor Grounding / Bonding Installation - SAIC-P-3739

EGC - Process Eqpt. Grounding / Bonding Installation - SAIC-P-3740

EGC - Structural Steel Grounding / Bonding Installation - SAIC-P-3741

EGC - LV Cable Grounding / Bonding Installation - SAIC-P-3742

EGC - MV Cable Grounding / Bonding / Shielding Installation - SAIC-P-3743

EGC - Raised Floor Grounding / Bonding Installation - SAIC-P-3744

EGC - Offshore Grounding / Bonding Installation - SAIC-P-3745

EGC - Fence Grounding / Bonding Installation - SAIC-P-3746

EGC - Tank Grounding / Bonding Installation - SAIC-P-3747

EGC - Static Electricity Grounding / Bonding Installation - SAIC-P-3748

EGC - Isolated Grounding / Bonding Installation - SAIC-P-3749

Grounding - Soil Resistivity Test Report (Jobsite Final Soil) - SATR-P-3701

Grounding - GES - Electrode Resistance Test (IEEE 81) - SATR-P-3702

Grounding - GES - Electrode Resistance Test (Geonics) - SATR-P-3703

Grounding - EGC - Continuity to GES Testing - SATR-P-3704

Grounding - GEC - Neutral Ground Resistor Testing - SATR-P-3705

Grounding - EGC - Ground Termination Torque Testing - SATR-P-3706


15 Lighting Protection Systems : SATIP-P-111-02

Lightning Protection Air Terminals Material Receiving - SAIC-P-3750

Lightning Protection Ground Terminals Material Receiving - SAIC-P-3751

Lightning Protection Cable Material Receiving - SAIC-P-3752

Lightning Protection Accessories Material Receiving - SAIC-P-3753

Lightning Protection Air Terminals Installation - SAIC-P-3754

Lightning Protection Ground Terminals Installation - SAIC-P-3755

Lightning Protection Loop / Down / Bonding Conductor Installation - SAIC-P-3756


16 LV Induction Motors : SATIP-P-113-01

LV SCIM - Motor Storage, Handling, and Preservation - SAIC-P-3407

LV SCIM - Explosion-Proof Motor Material Receiving - SAIC-P-3408

LV SCIM - Severe Duty TE Motor Material Receiving - SAIC-P-3409

LV SCIM - API Air-Cooled H/E Fan Motor Material Receiving - SAIC-P-3410

LV SCIM - Non-Industrial Facilities Motor Material Receiving - SAIC-P-3411

LV SCIM - Squirrel-Cage Induction Motor Installation and Pre-Commissioning - SAIC-P-3413

LV SCIM - Motor Storage - Space Heater Insulation Resistance and Functional Testing - SATR-P-3406

LV SCIM - Motor Insulation Resistance and Functional Testing - SATR-P-3407


17 M.V. Induction Motors (Nameplate Voltage: 4kV, 6.6kV & 13.2kV) : SATIP-P-113-02

MV Motor - Storage, Handling, and Preservation - SAIC-P-3414

MV Motor - Form Wound Squirrel Cage Induction Motor (SCIM) Material Receiving - SAIC-P-3415

MV Motor - Form Wound Synchronous Motor Material Receiving - SAIC-P-3416

MV Motor - Non-industrial Facilities Motor Material Receiving - SAIC-P-3417

MV Motor - Motor Accessories Material Receiving - SAIC-P-3418

MV Motor - Motor Installation and Pre-Commissioning - SAIC-P-3419

MV Motor - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3408

MV Motor - Form Wound SCIM Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3409

MV Motor -  Form Wound Synchronous Motor Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3410

MV Motor - Non-industrial Facilities Motor Insulation Resistance, Hi-Pot Withstand, and Functional Testing - SATR-P-3411


18 Diesel-Generator Set : SATIP-P-113-03

DG Set - Storage, Handling, and Preservation - SAIC-P-3420

DG Set - Engine and Synchronous Generator Material Receiving - SAIC-P-3421

DG Set - GCB, Voltage Regulator, Enclosure, Load Test Set, and DG Accessories Material Receiving - SAIC-P-3422

DG Set - Installation and Pre-Commissioning - SAIC-P-3423

DG Set - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3412

DG Set - Form Wound Synchronous Generator Insulation Resistance and Functional Testing - SATR-P-3413

Download SATIP Index xlsx  file

19 Cranes, Hoists and Elevators : SATIP-P-113-04

Cranes, Hoists, Elevators - Specialty Equipment and Accessories Material Receiving - SAIC-P-3424

Cranes, Hoists, Elevators - Installation and Pre-Commissioning - SAIC-P-3425

Crane Insulation Resistance and Functional Testing - SATR-P-3414

Hoist Insulation Resistance and Functional Testing - SATR-P-3415

Elevator Insulation Resistance and Functional Testing - SATR-P-3416


20 Annunciator Metering and Protection Relaying Cabinets : SATIP-P-114-01

Protection & Metering - Annunciator Panel Material Receiving - SAIC-P-3801

Protection & Metering - Metering Cabinet Material Receiving - SAIC-P-3802

Protection & Metering - Relay Cabinet Material Receiving - SAIC-P-3803

Protection & Metering - Current Transformer Material Receiving - SAIC-P-3804

Protection & Metering - Potential Transformer Material Receiving - SAIC-P-3805

Protection & Metering - Protection Relay Material Receiving - SAIC-P-3806

Protection & Metering - Electric Meter / Recorder Material Receiving - SAIC-P-3807

Protection & Metering - Accessories Material Receiving - SAIC-P-3808

Protection & Metering - Equipment Installation and Pre-Commissioning - SAIC-P-3809

Protection & Metering - CT and PT Installation and Pre-Commissioning - SAIC-P-3810

Protection & Metering - Relay Installation and Pre-Commissioning - SAIC-P-3811

Protection & Metering - Meter / Recorder Installation and Pre-Commissioning - SAIC-P-3812

Protection & Metering - Relay Calibration, Setting, and Functional Testing - SATR-P-3801

Protection & Metering - Meter / Recorder Calibration, Setting, and Functional Testing - SATR-P-3802

Protection & Metering - Annunciator Pre-energization and Functional Testing - SATR-P-3803

Protection & Metering - CT Pre-energization and Functional Testing - SATR-P-3804

Protection & Metering - PT Pre-energization and Functional Testing - SATR-P-3805


21 MV Switchgear : SATIP-P-116-01

MV Switchgear - Metal-Clad Switchgear (Indoor/Outdoor) Material Receiving - SAIC-P-3813

MV Switchgear - SF6 Switchgear (Outdoor) Material Receiving - SAIC-P-3814

MV Switchgear - Manual SF6 Circuit Breaker Material Receiving - SAIC-P-3815

MV Switchgear - Vacuum Circuit Breaker (Motor Load) Material Receiving - SAIC-P-3816

MV Switchgear - Vacuum Circuit Breaker (Feeder Load) Material Receiving - SAIC-P-3817

MV Switchgear - Accessories Material Receiving - SAIC-P-3818

MV Switchgear - Metal-Clad Switchgear Installation and Pre-Commissioning - SAIC-P-3819

MV Switchgear - SF6 Switchgear Installation and Pre-Commissioning - SAIC-P-3820

MV Switchgear - MV Manual SF6 Circuit Breaker Pre-Commissioning - SAIC-P-3821

MV Switchgear - MV Vacuum Circuit Breaker - Motor Load  Pre-Commissioning - SAIC-P-3822

MV Switchgear - MV Vacuum Circuit Breaker - Feeder  Pre-Commissioning - SAIC-P-3823

MV Switchgear / Controlgear - Jobsite Acceptance and Space Heater Functional Testing - SATR-P-3806

MV Switchgear - Metal-Clad Switchgear Pre-Energized and Functional Testing - SATR-P-3807

MV Switchgear - SF6 Switchgear, Pre-Energized and Functional Testing - SATR-P-3808

MV Switchgear - MV Manual SF6 Circuit Breaker Calibration, Setting, and Functional Testing - SATR-P-3809

MV Switchgear - MV Vacuum Circuit Breaker - Motor Load Calibration, Setting, and Functional Testing - SATR-P-3810

MV Switchgear - MV Vacuum Circuit Breaker - Feeder Calibration, Setting, and Functional Testing - SATR-P-3811


22 MV Controlgear : SATIP-P-116-02

MV Controlgear - Metal-Enclosed Equipment (Indoor/Outdoor) Material Receiving - SAIC-P-3824

MV Controlgear - Power Circuit Breaker Material Receiving - SAIC-P-3825

MV Controlgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3829

MV Controlgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3830

MV Controlgear - Fused Motor Controller Pre-Commissioning - SAIC-P-3831

MV Controlgear - Fused Switching Assembly Pre-Commissioning - SAIC-P-3832

MV Controlgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3812

MV Controlgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3813

MV Controlgear - Fused Motor Controller - Motor Load Calibration, Setting, and Functional Testing - SATR-P-3814

MV Controlgear - Fused Switching Assembly - Feeder Load Calibration, Setting, and Functional Testing - SATR-P-3815


23 LV Switchgear and Switchboards : SATIP-P-116-03

LV Switchgear - Indoor/Outdoor Equipment Material Receiving - SAIC-P-3833

LV Switchboard - Material Receiving - SAIC-P-3834

LV Switchgear - Power Circuit Breaker Material Receiving - SAIC-P-3835

LV Switchgear / Switchboard - Molded Case Breaker Material Receiving - SAIC-P-3836

LV Switchgear / Switchboard - Accessories Material Receiving - SAIC-P-3837

LV Switchgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3838

LV Switchgear / Switchboard - Molded Case Breaker Pre-Commissioning - SAIC-P-3839

LV Switchgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3840

LV Switchboard - Installation and Pre-Commissioning - SAIC-P-3841

LV Switchgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3816

LV Switchgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3817

LV Switchgear / Switchboard - Molded Case Circuit Breaker Calibration, Setting, and Functional Testing - SATR-P-3818


24 LV Controlgear TIP : SATIP-P-116-04

LV Controlgear - Metal-Enclosed Equipment (Indoor/Outdoor) Material Receiving - SAIC-P-3842

LV Controlgear - Power Circuit Breaker Material Receiving - SAIC-P-3843

LV Controlgear - Full Voltage Motor Controller Material Receiving - SAIC-P-3844

LV Controlgear - Reduced Voltage Motor Controller Material Receiving - SAIC-P-3845

LV Controlgear - Feeder Contactor Material Receiving - SAIC-P-3846

LV Controlgear - ATS / MTS Material Receiving - SAIC-P-3847

LV Controlgear - Accessories Material Receiving - SAIC-P-3848

LV Controlgear - Metal-Enclosed Equipment Installation and Pre-Commissioning - SAIC-P-3849

LV Controlgear - Power Circuit Breaker Pre-Commissioning - SAIC-P-3850

LV Controlgear - Full Voltage Motor Controller Pre-Commissioning - SAIC-P-3851

LV Controlgear - Reduced Voltage Motor Controller Pre-Commissioning - SAIC-P-3852

LV Controlgear - Feeder Contactor Pre-Commissioning - SAIC-P-3853

LV Controlgear - ATS / MTS Pre-Commissioning - SAIC-P-3854

LV Controlgear - Metal-Enclosed Equipment Pre-Energized and Functional Testing - SATR-P-3819

LV Controlgear - Power Circuit Breaker - Calibration, Setting, and Functional Testing - SATR-P-3820

LV Controlgear - Full Voltage Motor Controller Calibration, Setting, and Functional Testing - SATR-P-3821

LV Controlgear - Reduced Voltage Motor Controller Calibration, Setting, and Functional Testing - SATR-P-3822

LV Controlgear - Feeder Contactor Calibration, Setting, and Functional Testing - SATR-P-3823

LV Controlgear - ATS / MTS Calibration, Setting, and Functional Testing - SATR-P-3824


25 Switchracks and Distribution Racks : SATIP-P-116-05

Switchrack Material Receiving - SAIC-P-3855

Switchrack Pre-Commissioning - SAIC-P-3857


26 Fire Water Pump / Motor / Controller : SATIP-P-116-06

LV SCIM for Fire Water Pump Service Material Receiving - SAIC-P-3454

LV Severe Duty TE SCIM Material Receiving - SAIC-P-3455

LV SCIM for Non-Industrial Facilities (Jockey Pump Service) Material Receiving - SAIC-P-3456

LV Motor Controller for Fire Service Material Receiving - SAIC-P-3457 

Fire / Jockey Pump Motors & Controller Installation and Pre-Commissioning - SAIC-P-3458

Fire / Jockey Pump Motors & Controller Calibration, Settings, and Testing (Installed Motor) - SATR-P-3417


27 LV Panelboards : SATIP-P-116-07

LV Panelboard-Industrial Outdoor Panelboard(≤400A)Material Receiving - SAIC-P-3859

LV Panelboard - Non-Industrial Panelboard Material Receiving - SAIC-P-3860

LV Panelboard - Industrial Explosion-Proof Panelboard (≤400A) Material Receiving - SAIC-P-3862

LV Panelboard - Non-Hazardous AC/DC Panelboard Installation and Pre-Commissioning - SAIC-P-3867

LV Panelboard - Explosion-Proof Panelboard Installation and Pre-Commissioning - SAIC-P-3869

LV Panelboard - Pre-Energized and Functional Testing - SATR-P-3825


28 MV (max 35kV) Non-seg Busduct : SATIP-P-116-08

MV Non-Seg Busduct Material Receiving - SAIC-P-3239

MV Non-Seg Busduct Installation and Pre-Commissioning - SAIC-P-3241

MV Non-Seg Busduct Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3242

MV Non-Seg Busduct High-Potential Withstand Testing - SATR-P-3227

MV Non-Seg Busduct Torque Testing - SATR-P-3228

MV Non-Seg Busduct Continuity, Insulation, and Space Heater Functionality Testing - SATR-P-3229


29 MV (max. 15kV) Cablebus) : SATIP-P-116-10

MV Cablebus Framework Material Receiving - SAIC-P-3247

MV Cablebus Conductor Material Receiving - SAIC-P-3248

MV Cablebus Accessories Material Receiving - SAIC-P-3249

MV Cablebus Installation and Pre-Commissioning - SAIC-P-3250

MV Cablebus Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3251

MV Cablebus Continuity and Insulation Resistance Testing - SATR-P-3233

MV Cablebus Torque Testing - SATR-P-3234

MV Cablebus High-Potential Withstand Testing - SATR-P-3235


30 LV Non-seg Busduct : SATIP-P-116-11

LV Non-Seg Busduct Material Receiving - SAIC-P-3252

LV Non-Seg Busduct Accessories Material Receiving - SAIC-P-3253

LV Non-Seg Busduct Installation and Pre-Commissioning - SAIC-P-3254

LV Non-Seg Busduct Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3255

LV Non-Seg Busduct Torque Testing - SATR-P-3236

LV Non-Seg Busduct Continuity, Insulation, and Space Heater Functionality Testing - SATR-P-3237


31 LV Cablebus : SATIP-P-116-12

LV Cablebus Framework Material Receiving - SAIC-P-3256

LV Cablebus Conductor Material Receiving - SAIC-P-3257

LV Cablebus Accessories Material Receiving - SAIC-P-3258

LV Cablebus Installation and Pre-Commissioning - SAIC-P-3259

LV Cablebus Bulkhead Fire Barrier Installation and Pre-Commissioning - SAIC-P-3260

LV Cablebus Continuity and Insulation Resistance Testing - SATR-P-3238

LV Cablebus Torque Testing - SATR-P-3239

Download SATIP Index xlsx  file

32 VSD Equipment : SATIP-P-116-13

VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Material Receiving - SAIC-P-3426

VSD - Liquid Cooled LV AFD Material Receiving - SAIC-P-3427

VSD - Air Cooled MV AFD Material Receiving - SAIC-P-3428

VSD - Liquid Cooled MV AFD Material Receiving - SAIC-P-3429

VSD - Source Isolation Transformer Material Receiving - SAIC-P-3430

VSD - Induction Motors Material Receiving - SAIC-P-3431

VSD - DC Link Reactor Material Receiving - SAIC-P-3432

VSD - Cooling Liquid Pumps Material Receiving - SAIC-P-3433

VSD - Cooing Fans Material Receiving - SAIC-P-3434

VSD - Cooling Liquid Piping Material Receiving - SAIC-P-3435

VSD - Cooling System Valves Material Receiving - SAIC-P-3436

VSD - Painting / Coating / Insulation Material Receiving - SAIC-P-3437

VSD - Cooling System Heat Exchanger Material Receiving - SAIC-P-3438

VSD - Cooling Control System Material Receiving - SAIC-P-3439

VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Material Receiving - SAIC-P-3440

VSD - Liquid Cooled LV AFD Installation and Pre-Commissioning - SAIC-P-3441

VSD - Air Cooled MV AFD Installation and Pre-Commissioning - SAIC-P-3442

VSD - Liquid Cooled MV AFD Installation and Pre-Commissioning - SAIC-P-3443

VSD - Source Isolation Transformer Installation and Pre-Commissioning - SAIC-P-3444

VSD - Induction Motors Installation and Pre-Commissioning - SAIC-P-3445

VSD - DC Link Reactor Installation and Pre-Commissioning - SAIC-P-3446

VSD - Cooling Liquid Pumps Installation and Pre-Commissioning - SAIC-P-3447

VSD - Cooing Fans Installation and Pre-Commissioning - SAIC-P-3448

VSD - Cooling Liquid Piping Installation and Pre-Commissioning - SAIC-P-3449

VSD - Cooling System Valves Installation and Pre-Commissioning - SAIC-P-3450

VSD - Painting / Coating / Insulation Installation and Pre-Commissioning - SAIC-P-3451

VSD - Cooling System Heat Exchanger Installation and Pre-Commissioning - SAIC-P-3452

VSD - Cooling Control System Installation and Pre-Commissioning - SAIC-P-3453

VSD - Air Cooled LV Adjustable Frequency Drive (AFD) Pre-Energizing and Functional Testing - SATR-P-3418

VSD - Liquid Cooled LV AFD Pre-Energizing and Functional Testing - SATR-P-3419

VSD - Air Cooled MV AFD Pre-Energizing and Functional Testing - SATR-P-3420

VSD - Liquid Cooled MV AFD Pre-Energizing and Functional Testing - SATR-P-3421

VSD - Source Isolation Transformer Pre-Energizing and Functional Testing - SATR-P-3422

VSD - Induction Motors Pre-Energizing and Functional Testing - SATR-P-3423

VSD - DC Link Reactor Pre-Energizing and Functional Testing - SATR-P-3424

VSD - Cooling Liquid Pumps Pre-Energizing and Functional Testing - SATR-P-3425

VSD - Cooing Fans Pre-Energizing and Functional Testing - SATR-P-3426

VSD - Cooling Liquid Piping Pre-Energizing and Functional Testing - SATR-P-3427

VSD - Cooling System Valves Pre-Energizing and Functional Testing - SATR-P-3428

VSD - Painting / Coating / Insulation Pre-Energizing and Functional Testing - SATR-P-3429

VSD - Cooling System Heat Exchanger Pre-Energizing and Functional Testing - SATR-P-3430

VSD - Cooling Control System Pre-Energizing and Functional Testing - SATR-P-3431


33 HV Switchyard : SATIP-P-119-01

Switchyard - ACSR Cable and Accessories Storage, Handling, and Preservation - SAIC-P-3901

Switchyard - HV Equipment Storage, Handling, and Preservation - SAIC-P-3902

Switchyard -  Seamless Aluminum Bus Pipe and Accessories Material Receiving and Storage - SAIC-P-3903

Switchyard - Aluminum Conductor Steel Reinforced (ACSR) Cable and Accessories Material Receiving - SAIC-P-3904

Switchyard - HV SF6 C/B's and Switchgear Material Receiving - SAIC-P-3905

Switchyard - HV Post Insulators Material Receiving - SAIC-P-3906

Switchyard - HV Surge Arrestors and Capacitors Material Receiving - SAIC-P-3907

Switchyard - HV Disconnect Switches (Motor-operated and manual) Material Receiving - SAIC-P-3908

Switchyard - HV Metering and Protection CT's & PT's Material Receiving - SAIC-P-3909

Switchyard - HV SF6 C/B's and Switchgear Installation and Pre-Commissioning - SAIC-P-3910

Switchyard - HV Post Insulators Installation and Pre-Commissioning - SAIC-P-3911

Switchyard - HV Surge Arrestors and Capacitors Installation and Pre-Commissioning - SAIC-P-3912

Switchyard - HV Disconnect Switches (Motor-operated and manual) Installation and Pre-Commissioning - SAIC-P-3913

Switchyard - HV Metering and Protection CT's & PT's Installation and Pre-Commissioning - SAIC-P-3914

Switchyard -  Seamless Aluminum Bus Pipe and Accessories Installation and Pre-Commissioning - SAIC-P-3915

Switchyard - Aluminum Conductor Steel Reinforced (ACSR) Cable and Accessories Installation and Pre-Commissioning - SAIC-P-3916

Switchyard -  HV Mechanical Termination Torque Testing - SATR-P-3901

Switchyard -  HV Conductor (Pipe and ACSR) Continuity and Conductivity Testing - SATR-P-3902

Switchyard -  HV Ground Electrode System Continuity and Resistance Testing - SATR-P-3903

Switchyard -  HV Conductor (Pipe and ACSR) High-Potential Withstand Testing - SATR-P-3904

Switchyard - HV SF6 C/B's and Switchgear Pre-Energization and Functional Testing - SATR-P-3905

Switchyard - HV Disconnect Switches (Motor-operated and manual) Pre-Energization and Functional Testing - SATR-P-3906


34 Dry Type Transformers : SATIP-P-121-01

Dry Transformer - LV Non-Vented Xfmr (≤500 kVA, LV Pri) Material Receiving and Storage - SAIC-P-3918

Dry Transformer - MV Xfmr (MV or ≥501 kVA) Material Receiving and Storage - SAIC-P-3919

Dry Transformer - LV Xfmr (≤500 kVA, LV Pri) Assembly, Installation and Pre-Commissioning - SAIC-P-3920

Dry Transformer - MV Xfmr (MV or ≥501 kVA) Assembly, Installation and Pre-Commissioning - SAIC-P-3921

Dry Transformer - LV Xfmr (≤500 kVA, LV Pri) Pre-Commissioning and Functional Testing - SATR-P-3907

Dry Transformer - MV Xfmr (MV or ≥501 kVA) Pre-Commissioning and Functional Testing - SATR-P-3908


35 Power Transformers : SATIP-P-121-02

Power Transformer - Storage, Handling, and Preservation - SAIC-P-3922

Power Transformer - Material Receiving - SAIC-P-3923

Power Transformer Accessories - Material Receiving - SAIC-P-3924

Power Transformer - Installation, Assembly, and Filling - SAIC-P-3925

Power Transformer - Pre-Commissioning and Energization - SAIC-P-3926

Power Transformer Pressure - Storage, Handling, and Installaiton - SATR-P-3909

Power Transformer Vibration Event - Storage, Handling, and Installation - SATR-P-3910

Power Transformer Tank - Jobsite Acceptance Test - SATR-P-3911

Power Transformer - Jobsite Testing - SATR-P-3912


36 Overhead Transformers : SATIP-P-121-03

Overhead Transformer - Material Receiving - SAIC-P-3927

Overhead Transformer Accessories - Material Receiving - SAIC-P-3928

Overhead Transformer - Installation, Assembly, and Filling - SAIC-P-3929

Overhead Transformer - Pre-Commissioning and Energization - SAIC-P-3930

Overhead Transformer - Jobsite Acceptance Test - SATR-P-3913

Overhead Transformer - Jobsite Testing - SATR-P-3914


37 Pad Mounted Transformers : SATIP-P-121-04

Self-Cooled Pad-Mounted MV Transformer - Material Receiving - SAIC-P-3931

Self-Cooled Pad-Mounted MV Transformer Accessories - Material Receiving - SAIC-P-3932

Self-Cooled Pad-Mounted MV Transformer - Installation, Assembly, and Filling - SAIC-P-3933

Self-Cooled Pad-Mounted MV Transformer - Pre-Commissioning and Energization - SAIC-P-3934

Self-Cooled Pad-Mounted MV Transformer - Jobsite Acceptance Test - SATR-P-3915

Self-Cooled Pad-Mounted MV Transformer - Jobsite Testing - SATR-P-3916


38 Light Fixtures and Lighting Systems : SATIP-P-123-01

Fluorescent Light Fixtures - Material Receiving - SAIC-P-3610

HID Light Fixtures - Material Receiving - SAIC-P-3611

Emergency Light Fixtures - Material Receiving - SAIC-P-3612

Incandescent Light Fixtures - Material Receiving - SAIC-P-3613

12V High Intensity Incandescent Fixtures - Material Receiving - SAIC-P-3614

Aviation / Obstruction Light Fixtures - Material Receiving - SAIC-P-3615

Lighting Accessories - Material Receiving - SAIC-P-3616

Light Pole Assembly and Installation - SAIC-P-3617

Hung Ceiling Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3618

Surface Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3619

Flush Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3620

HID High-bay Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3621

HID Low-bay Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3622

Lighting Control System - Installation and Pre-Commissioning - SAIC-P-3623

Pole-Mounted Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3624

Security Light Fixtures (Fence, Area, and Checkpoint Ltg.) - Assembly, Installation, and Pre-Commissioning - SAIC-P-3625

Aviation / Obstruction Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3626

Offshore Light Fixtures - Assembly, Installation, and Pre-Commissioning - SAIC-P-3627

Area & Street Lighting (point to point) - Illumination Level Testing - SATR-P-3610

Interior Lighting (zone cavity) - Illumination Level Testing - SATR-P-3611

Sports Lighting - Illumination Level Testing - SATR-P-3612

Security Lighting (Fence, Area, and Checkpoint Ltg.) - Illumination Level Testing - SATR-P-3613

Aviation / Obstruction Light Fixtures - Illumination Level Testing - SATR-P-3614

Offshore Lighting - Illumination Level Testing - SATR-P-3615


39 Factory Assembled (Packaged) Auxiliary Electrical Equipment : SATIP-P-515-01

General Mechanical Equipment Skid for Zone or Div 1 - Material Receiving - SAIC-P-3019

General Mechanical Equipment Skid for Zone or Div 2 - Material Receiving - SAIC-P-3020

General Mechanical Equipment Skid for Non-Hazardous Locations - Material Receiving - SAIC-P-3021

General Mechanical Equipment Skid for Corrosive locations - Material Receiving - SAIC-P-3022

General Electrical Workspace Clearances - SAIC-P-3023


40 Off-Plot Galvanic Cathodic Protection : SATIP-X-400-01

Exothermic Welding Tools & Materials - Material Receiving - SAIC-X-3001

CP Accessories - Material Receiving - SAIC-X-3002

Exothermic Welding - SAIC-X-3003

Galvanic Anodes for CP (Aluminum, Magnesium, and Zinc Anodes) - Material Receiving - SAIC-X-3101

Galvanic CP Test Stations / Junction Boxes - Material Receiving - SAIC-X-3102

Galvanic CP Anode Installation and Pre-Commissioning - SAIC-X-3103

Galvanic CP Test Station Installation and Pre-Commissioning - SAIC-X-3104

Galvanic CP Cable Installation, Termination, and Identification - SAIC-X-3105

Galvanic CP Testing - SATR-X-3101

Galvanic CP Anode Installation and Pre-Commissioning - SATR-X-3103


41 Off-Plot Impressed Current Cathodic Protection : SATIP-X-400-02

DC Cable Holiday Testing - SATR-X-3201

Impressed Current CP Testing - SATR-X-3202

Plant Potential Survey Testing - SATR-X-3203

External Tank Bottom Testing - SATR-X-3204

Internal Tank Potential Testing - SATR-X-3205


42 On-plot Galvanic Cathodic Protection : SATIP-X-600-02

CP Rectifier - Material Receiving - SAIC-X-3201

Impressed Current Anode - Material Receiving - SAIC-X-3202

Impressed Current CP Cable - Material Receiving - SAIC-X-3203

DC Rectifier Installation and Pre-Commissioning - SAIC-X-3204

Impressed Current CP Anode Installation and Pre-Commissioning - SAIC-X-3205

Impressed Current CP Deep Anode Bed Installation and Pre-Commissioning - SAIC-X-3206

Impressed Current CP Cable Installation, Termination, and Identification - SAIC-X-3207


SATIP INDEX  ELECTRICAL XLSX 
Download SATIP Index xlsx  file
ELECTRICAL INSPECTION CHECKLISTS AND TEST REPORTS INDEX 

Click Here
>> Download Excel File <<

Post a Comment

0Comments

Post a Comment (0)